Обзоры / System Error Codes HP 8000S

Главная / Обзоры / System Error Codes HP 8000S

System Error Codes HP 8000S


System Error 1010: ATG/RSM Loading Error  

The program load from the Flash ROM on the Main PCA to the ASIC on the
Main PCA or sum-check was not performed correctly and an error occurred.


System Error 1011: PTC/PDD Loading Error

The program load from the Flash ROM on the Main PCA to the ASIC on the
Carriage PCA or sum-check was not performed correctly and an error
occurred.


System Error 1100: Flash ROM Error

The program area in the Flash ROM is sum-checked, and it could not be
read, causing an error.


System Error 1101: ATG/RSM Error

The read/write of the ATG/RSM registers and RSM Mask Memory Data on
the Main PCA was diagnosed and an error was detected.


System Error 1102: Trailing Cable Error

The Trailing Cable between the Main PCA and the Carriage PCA is not
connected.


System Error 1103: Heater Relay Board Connection Error

The Cable between the Main PCA and the Heater Relay Board is not
connected.


System Error 1104: ISS PCA Connection Error

The Cable between the Main PCA and the ISS PCA is not connected


System Error 1105: PTC/PDD Error

The PTC/PDD registers cannot be read or written correctly.


System Error 1106: Power Error

The power supplies of +36, +24 and +12 V were diagnosed and could not
be detected. This error is checked when the Printer is booted up.


System Error 1107: Carriage Interface Error

The Carriage Interface is not connect correctly.


System Error 1108: USB Error

USB communication is not performed correctly.


System Error 1109: EEPROM Error

The parameters saved in the EEPROM on the Main PCA cannot be read
correctly.


System Error 110A: Band Memory Error

The read/write of the SDRAM (band memory) on the Main PCA was
diagnosed and an error was detected.


System Error 110B: Cap Horizontal Position Error

The Cap horizontal position is defined as 0.0 mm.


System Error 1110: Data Path Time-out Error

The data transfer via USB from the host does not finish even when a
specified time period has passed.


System Error 112x: Vacuum Fan Error

 x = 0: The Vacuum Fan 1 (extreme right of the printer) has failed.
 x = 1: The Vacuum Fan 2 (center right of the printer) has failed.
 x = 2: The Vacuum Fan 3 (center left of the printer) has failed.
 x = 3: The Vacuum Fan 4 (extreme left of the printer) has failed.


System Error 1130: DMA Controller Error.

An error occurs when the DMA of the printing data cannot be completed.


System Error 1140: Flash ROM Write Error

A time-out error occurs when the flash ROM contents are being saved and
erasing does not end.


System Error 1150: Home Position Sensor Error

The Carriage cannot be moved to it’s home position.


System Error 1160: Wiping Error

When the Wiping Motor has been running for a while, the sensor fails to
detect that the Motor has made one turn.


System Error 1170: Temperature Sensor Error

The Temperature Sensor detects abnormal temperatures (-10oC or lower or
85oC or higher).


System Error 1180: Pump/Wipe Motor Error

Over current is detected in the pump/wipe motor drive circuit.


System Error 119x: Printhead Drive Voltage Error

The Printhead drive voltages generated on the Carriage PCA do not reach
the expected values.


System Error 11A0: EEPROM I/O Error

The read/write of the EEPROM on the Main PCA was diagnosed and an
error was detected.


System Error 11D0: Printhead Cooling Fan Error

The Printhead temperature does not drop even after the printhead Cooling
Fan rotates for more than a specified time.


System Error 11E0: Long Term Storage Error

This error is displayed when the Printer has been left switched OFF for more
than 31 days.

This error can be avoided if the "Store Ink System" procedure is performed
before turning the Printer OFF for long periods.
To clear this error:
– Turn the Printer ON in error skip mode by holding down the Cancel
and Shift keys and pressing the ON button.
– Enter the Password to clear the internal error flag: <-, ->, Shift and OK.
– Switch the Printer OFF and then ON again.


System Error 120x: Printhead Drive IC Error

The Piezo Drive IC on a Printhead is either too hot (85oC or higher) or too
low (-10oC or lower).


System Error 1220: Line Sensor Error

The Printer has problems detecting the edge of the Media.


System Error 126x: Trailing Cable Connection Error

The Trailing Cable connected to the one of the following connectors on the
Carriage PCA is faulty.
 x = 0: Connector 9.
 x = 1: Connector 10.
 x = 2: Connector 11.
 x = 3: Connector 12.


System Error 1290: End of Life of Part Reached

The end of life of the Prime Assembly has been reached since it has been
working for more than 43 hours.


System Error 1310: Cap Sensor Error

The cap home position cannot be found.


System Error 1320: Scan-Axis Motor Heating Error

The Scan-Axis Motor Temperature Sensor has detected a temperature over
100oC.


System Error 1330: Scan-Axis Motor Temperature Sensor Error

The Scan-Axis Motor Temperature Sensor has detected abnormal
temperatures (-22.5oC or lower or 150oC or higher).


System Error 140x: Heater Temperature Error

Temperature read by the Heater Temperature Sensor is abnormal (lower than
-20oC or higher than 200oC).
x = 1: Front heater.
x = 2: Center Platen.
x = 3: Rear Heater.


System Error 141x: Heater Error (High Temperature)

Temperature read by the Heater Temperature Sensor is above 65oC).

x = 1: Front heater.
x = 2: Center Platen.
x = 3: Rear Heater.


System Error 143x: Heater Error (Insufficient Heating)

The Heater is not heated to a specified temperature even after 30 minutes
have passed.
 x = 1: Front heater.
 x = 2: Center Platen.
 x = 3: Rear Heater.


System Error 144x: Heater Error (No Interrupt)

No heater sequence interrupt.


System Error 2000 to 6000: Firmware Logic Error

A logic error has occurred in the Firmware program.